Jamestown175 Series 45 Minute Fire Rated Steel Windows
OPENING SIZE:
 |
Maximum Opening
Area: |
149 sq. ft. |
 |
Maximum Dimension
(HT): |
10.96 ft. (131-1/2”) |
 |
Maximum Dimension
(WD): |
13.63 ft. (163-1/2”) |
| |
|
|
SASH SIZE:
 |
Maximum Sash Area: |
55 sq. ft. |
 |
Maximum Dimension
(HT): |
10.92 ft. (131”) |
 |
Maximum Dimension
(WD): |
8.27 ft. (99-1/4”) |
| |
|
|
VENTILATOR SIZE:
 |
Maximum Side Hung
Casement: |
38-1/8” (WD)
x 72-3/8” (HT) |
 |
Maximum Top Hung: |
58-3/8” (WD)
x 60-1/8” (HT) |
| |
|
|
GLASS SIZE:
The following maximum dimensions are Hope’s window limitations for glass, based on actual fire testing. The final glass size must be determined between the glass manufacturer’s size limitations and Hope’s window limitations. The lesser of the two must be followed.
 |
Maximum Glass Area: |
4,164 sq. in. |
 |
Maximum Dimension
(HT): |
95-3/16” |
 |
Maximum Dimension
(WD): |
58-5/8” |
No combinations of width and height dimensions can exceed
4,164 sq. in.
Examples:
 |
If height is 95-3/16”,
then maximum width can be no greater than 43-3/4” to equal 4,164 sq.
in. |
 |
If width is 58-5/8”,
then maximum height can be no greater than 71” to equal 4,164 sq. in. |
| |
|
Consult Hope’s for assistance in determining between the glass manufacturer’s size limitations and
Hope’s window limitations.
Jamestown175 Series 45 Minute Fire Rated Steel Doors
OPENING SIZE:
 |
Maximum Opening
Area: |
149 sq. ft. |
 |
Maximum Dimension
(HT): |
10.96 ft. (131-1/2”) |
 |
Maximum Dimension
(WD): |
13.63 ft. (163-1/2”) |
| |
|
|
DOOR FRAME SIZE:
 |
Maximum Door Frame
Area: |
55.79 sq. ft. (double)
/ 29 sq. ft. (single) |
 |
Maximum Dimension
(HT): |
8.00 ft. (96”) |
 |
Maximum Dimension
(WD): |
7.00 ft. (84”
- double) / 3.69 ft. (44-5/16” - single) |
| |
Combined door frame with overhead fixed transom |
 |
Maximum Dimension
(WD): |
84” |
 |
Maximum Dimension
(HT): |
131” |
| |
|
|
DOOR SIZE:
 |
Maximum Dimension
(WD): |
7.00 ft. (84”
- double) / 3.69 ft. (44-5/16” - single) |
 |
Maximum Dimension
(HT): |
8.00 ft. (96”) |
| |
|
|
GLASS SIZE:
The following maximum dimensions are Hope’s glass size limitations, based on actual fire testing. The final glass size must be determined between the glass manufacturer’s size limitations and Hope’s window limitations. The lesser of the two must be followed.
 |
Maximum Glass Area: |
1,755 sq. in. |
 |
Maximum Dimension
(HT): |
47-11/16” |
 |
Maximum Dimension
(WD): |
36-13/16” |
No combinations of width and height dimensions can exceed
1,755 sq. in.
Consult Hope’s for assistance in determining the glass manufacturer’s size limitations and Hope’s
window limitations.
5000 Series 45 Minute Fire Rated Steel Doors
OPENING SIZE:
 |
Maximum Opening
Area: |
149 sq. ft. |
 |
Maximum Dimension
(HT): |
10.96 ft. (131-1/2”) |
 |
Maximum Dimension
(WD): |
13.63 ft. (163-1/2”) |
| |
|
|
SASH SIZE:
 |
Maximum Door Area: |
64 sq. ft. (double)
/ 32 sq. ft. (single) |
 |
Maximum Dimension
(HT): |
8.01 ft. (96-1/8”) |
 |
Maximum Dimension
(WD): |
8.00 ft. (96”-double)
/ 4.00 ft. (48” – single) |
| |
|
|
GLASS SIZE:
The following maximum dimensions are Hope’s window limitations for glass, based on actual fire testing. The final glass size must be determined between the glass manufacturer’s size limitations and Hope’s window limitations. The lesser of the two must be followed.
 |
Maximum Glass Area: |
3,736 sq. in. |
 |
Maximum Dimension
(HT): |
89-3/4” |
 |
Maximum Dimension
(WD): |
41-11/16” |
No combinations of width and height dimensions can exceed 3,736 sq. in.
Consult Hope’s for assistance in determining the glass manufacturer’s size limitations and Hope’s
window limitations.
7000 Series 60, 90 or 120 Minute Fire Rated Steel Doors
OPENING SIZE:
There are no limitations for opening size. The opening size can be any width or height providing the impost will meet the required glass and wind load requirements.
SASH SIZE:
 |
Maximum Door Area: |
64 sq. ft. (double)
/ 32 sq. ft. (single) |
 |
Maximum Dimension
(HT): |
8.01 ft. (96-1/8”) |
 |
Maximum Dimension
(WD): |
8.00 ft. (96”-double)
/ 4.00 ft. (48” – single) |
| |
|
|
GLASS SIZE:
The following maximum dimensions are Hope’s window limitations for glass, based on actual fire testing. The final glass size must be determined between the glass manufacturer’s size limitations and Hope’s window limitations. The lesser of the two must be followed.
 |
Maximum Glass Area: |
3,844 sq. in. |
 |
Maximum Dimension
(HT): |
86-5/8” |
 |
Maximum Dimension
(WD): |
44-5/8” |
No combinations of width and height dimensions can exceed 3,844 sq. in.
Consult Hope’s for assistance in determining the glass manufacturer’s size limitations and Hope’s
window limitations.
|