HOPE’S Steel & Bronze Windows & Doors

HURRICANE AND IMPACT RESISTANT

Fixed, side hung-out casement and project-out windows along with our swinging and slide and fold doors have been tested and exceed the Dade County protocols.

Review Full-Size Details in PDF Format

QUICK REFERENCE

Download DWG and DXF Drawing Files

DXF and DWG files require Autodesk® products or another compatible CAD program. Autodesk® has a drawing file reader Autodesk® Design Review, which you can download for free, enabling you to view CAD drawing files.

Fixed, Projected, and Casement Windows

Details shown with:

  • Fixed, Projected and Casement Windows
  • Interior glazed with 1-7/32" glass
  • Exterior glazed with 15/32" glass with sloped bead
  • Glazing beads

Swinging Doors

Details shown with:

  • Interior glazed with 1-7/32" glass
  • Exterior glazed with 15/32" glass with sloped bead
  • Glazing beads

Slide and Fold Doors

Details shown with:

  • Interior glazed with 19/32" glass
  • Exterior glazed with 14/32" glass

Shared Details and Support

Details shown with:

  • Simulated Divided Lites
  • Glazing Details
  • Insect Screens
  • Installation Application

Hardware

Details shown with:

  • Commercial hardware applications

Download Specifications

Microsoft Word DOC format conforming to CSI MasterFormat specification system

Size Capabilities

All window configurations are engineered for each specific project.

Consult Hope's for design recommendations.

Product Performance

  • All approved products were tested in accordance with the test protocols for High Velocity Hurricane Zones listed in the Florida Building Code
  • Air Infiltration Test: TAS 202 (PA 202); <.01 cfm/ft2 at 1.57 psf (windows); .18 cfm/ft2 at 1.57 psf (doors)
  • Uniform Static Air Pressure Test: TAS 202 (PA 202); Passed at 120 psf / 80 psf (windows); Passed at 97.5 psf / 65 psf (doors)
  • Water Resistance Test: TAS 202 (PA 202); No entry at 12 psf (windows); No entry at 9.75 psf (doors)
  • Large Missile Impact Test: TAS 201 (PA 201); Passed (windows and doors)
  • Cyclic Wind Pressure Test: TAS 203 (PA 203); Passed (windows and doors)
  • Forced Entry Test: SFBC 3603.2 (b) and TAS 202; Passed (windows and doors)
  • Impact Rating: Large and Small Missile
  • Design Pressure Rating (positive): 80 psf (windows); 65 psf (doors)
  • Design Pressure Rating (negative): 80 psf (windows); 65 psf (doors)